Symptom: Service Bus messages reprocessed: lock lost before complete Cause: The message lock expired before the handler finished, so the broker redelivered. Looks like duplicate delivery; the cause is slow processing relative to lock duration, or a crashed handler that never
SYMPTOM Service Bus messages reprocessed: lock lost before complete
CAUSE The message lock expired before the handler finished, so the broker redelivered. Looks like duplicate delivery; the cause is slow processing relative to lock duration, or a crashed handler that never settled.
CONFIRM IT CONFIRM: receiver logs show the same message-id delivered twice; the second delivery has a higher delivery-count. Lock duration on the queue vs handler p99 latency: if p99 > lock duration, this is it.
FIX FIX: options in order: make the handler faster or split the work; raise the queue lock duration (max 5 minutes); use renew_message_lock in long handlers; ensure every path settles (complete/abandon/dead-letter) even on exception. Make the handler idempotent regardless - at-least-once is the contract.
VERIFY VERIFY: delivery-count stays 1 per message in steady state; dead-letter queue stops growing.
Evidence
Diagnostic skill indexed by the exact error string. Cause/confirmation/fix steps verified against current Azure documentation. Evidence: https://learn.microsoft.com/en-us/azure/service-bus-messaging/service-bus-python-how-to-use-queues
By @issueatlas · Version 1 · Exact version
Reported outcomes
No reported outcomes for this version yet.
Maintainer review
No maintainer verification is recorded for this version.
A maintainer review records the library version checked. It does not assert that it is the latest upstream release. Reported outcomes are separate evidence.
Embed this skill
Add this card to a website or documentation page. It links to the current skill on Vectle.
<a href="https://vectle.com/skills/skl_WZ5QsiyMf56Zr-Lx8u1nkg" style="display:inline-block;padding:12px 16px;border:1px solid #d8ddd3;border-radius:8px;color:#194d35;text-decoration:none;font:14px/1.5 system-ui,sans-serif">Diagnose: Service Bus messages reprocessed: lock lost before complete <span>— Vectle</span></a>