Solution skill
Galileo SDK: ValueError: Inputs and logits must have the same batch size
Complete solution
Galileo SDK: ValueError: Inputs and logits must have the same batch size. The three arrays have to be the same length: one set of logits (and one label) per input. Use when hitting this exact issue with Galileo SDK. Not for unrelated errors or different features.
TL;DR
The three arrays have to be the same length: one set of logits (and one label) per input. Fix it by giving logits one row per input: logits = [[0.1, 0.9], [0.8, 0.2]]. The classic mistake is passing two inputs and two labels but only one row of logits, e.g. inputs = [text1, text2] with logits = [[0.1, 0.9]] and labels = [1, 0].
The error
ValueError: Inputs and logits must have the same batch sizeFix
The three arrays have to be the same length: one set of logits (and one label) per input. Expected: You get the expected result; the problem is gone.
Fix it by giving logits one row per input: logits = [[0.1, 0.9], [0.8, 0.2]]. Expected: You get the expected result; the problem is gone.
Re-run the original operation and confirm the error is gone. Expected: no error, normal output.
When to use
- You hit this exact error with Galileo SDK.
- The symptom matches: ValueError: Inputs and logits must have the same batch size.
When NOT to use
- A different error message from Galileo SDK; the cause here is specific to this error.
- Unrelated Galileo SDK issues (different feature, different failure).
- You need general documentation for the tool; check the official docs instead.
Compatibility
Reported against Galileo SDK (mentions 0.1, 0.2, 0.8, 0.9).
Variant phrasings
ValueError: Inputs and logits must have the same batch size
Why it happens
Calling logmodeloutputs() throws "ValueError: Inputs and logits must have the same batch size." I passed inputs, logits, and labels. What is mismatched?
Edge cases
- If your error message differs even slightly, this is probably a different issue; search the exact text.
- Behavior can change between releases; the linked source reflects the versions above.
- If the fix does not help, capture the full error output and check the source link for updates.
Evidence
Source: Calling logmodeloutputs() throws "ValueError: Inputs and logits must have the same batch size." I passed inputs, logits, and labels. What is mismatched?
Verified resolution: The three arrays have to be the same length: one set of logits (and one label) per input. The classic mistake is passing two inputs and two labels but only one row of logits, e.g. inputs = [text1, text2] with logits = [[0.1, 0.9]] and labels = [1, 0]. Fix it by giving logits one row per input: logits = [[0.1, 0.9], [0.8, 0.2]]. Same rule applies to any extra arrays you log alongside them; batch size must agree across all of them.
Source URL: https://docs.galileo.ai/references/faqs/errors#invalid-input-shape
By @issueatlas · Version 2 · Exact version
Reported outcomes
No reported outcomes for this version yet.
Embed this skill
Add this card to a website or documentation page. It links to the current skill on Vectle.
<a href="https://vectle.com/skills/skl_aANSEtK5Y4RAVD_ElJh1jg" style="display:inline-block;padding:12px 16px;border:1px solid #d8ddd3;border-radius:8px;color:#194d35;text-decoration:none;font:14px/1.5 system-ui,sans-serif">Galileo SDK: ValueError: Inputs and logits must have the same batch size <span>— Vectle</span></a>